Power Consumption Modeling of Data Center IT Room with Distributed Air Flow
X Zhang, T Lindberg, K Svensson, V Vyatkin… - International Journal of …, 2016
Abstract Modern data centers are characterized by large sizes, high energy consumption
and complexity involving IT, power supply, ventilation and cooling. Data center energy
efficiency is a major concern for data center design and operation. To improve data center ...
and complexity involving IT, power supply, ventilation and cooling. Data center energy
efficiency is a major concern for data center design and operation. To improve data center ...
TEMPERATURE DISTRIBUTION PREDICTION METHOD AND AIR CONDITIONING MANAGEMENT SYSTEM
T Kasajima, M Ogawa, M Ishinabe, K Uno, H Fukuda… - US Patent 20,160,061,668, 2016
... management. A data center is installed as a facility for collectively managing data. In
a data center, a number of racks (sever racks) are installed in the computer room and
a plurality of computers is accommodated in each of the racks. ...
a data center, a number of racks (sever racks) are installed in the computer room and
a plurality of computers is accommodated in each of the racks. ...
RELEASABLE, THREADLESS CONDUIT CONNECTOR FOR LIQUID MANIFOLD
TJ Brunschwiler, EG Colgan, MJ Ellsworth Jr… - US Patent 20,160,061,364, 2016
... which: FIG. 1 depicts one embodiment of a conventional raised floor layout of an
air-cooled data center; FIG. ... herein. Further, “data center” refers to a computer
installation containing one or more electronics racks to be cooled. ...
air-cooled data center; FIG. ... herein. Further, “data center” refers to a computer
installation containing one or more electronics racks to be cooled. ...
Alkenone paleothermometry in the North Atlantic: A review and synthesis of surface sediment data and calibrations
A Filippova, M Kienast, M Frank, RR Schneider - Geochemistry, Geophysics, …, 2016
Page 1. Alkenone paleothermometry in the North Atlantic: A review and synthesis of surface
sediment data and calibrations A. Filippova GEOMAR Helmholtz Centre for Ocean Research
Kiel, 24148 Kiel, Germany (afilippova@geomar.de) M. Kienast ...
sediment data and calibrations A. Filippova GEOMAR Helmholtz Centre for Ocean Research
Kiel, 24148 Kiel, Germany (afilippova@geomar.de) M. Kienast ...
Evolving the practice of Regional Integrated Sciences and Assessments
A Parris, SL Close, R Meyer, K Dow, G Garfin - Climate in Context: Science and …, 2016
SYSTEM AND METHODS FOR DETERMINING SENSITIZATION OF ALLOY BY MEASURING AND CORRELATING ULTRASONIC PARAMETERS
G Petculescu - US Patent 20,160,061,781, 2016
... etc. The communications interface allows communication through transferred signals
between the client computer 902 and external devices including networks such as
the Internet 904 and cloud data center 906. Communication ...
between the client computer 902 and external devices including networks such as
the Internet 904 and cloud data center 906. Communication ...
[HTML] Difference between forward-and backward-looking bands of GOSAT-2 CAI-2 cloud discrimination used with Terra MISR data
Y Oishi, TY Nakajima, T Matsunaga - International Journal of Remote Sensing, 2016
The use of SESK as a trend parameter for localized bearing fault diagnosis in induction machines
L Saidi, JB Ali, M Benbouzid, E Bechhoefer - ISA Transactions, 2016
A critical work of bearing fault diagnosis is locating the optimum frequency band that contains
faulty bearing signal, which is usually buried in the noise back.
faulty bearing signal, which is usually buried in the noise back.
Managing the 2011 drought: a climate services partnership
M Shafer, D Brown, C McNutt - Climate in Context: Science and Society Partnering for …, 2016
Climate science for decision-making in the New York metropolitan region
R Horton, C Rosenzweig, W Solecki, D Bader, L Sohl - Climate in Context: Science …, 2016
No comments:
Post a Comment