Research Readings in Cloud

… -RAY SKY AFTER 1000 INTEGRAL ORBITSBased on observations with INTEGRAL, an ESA project with instruments and a science data centerfunded by ESA …

AJ Bird, A Bazzano, A Malizia, M Fiocchi, V Sguera… - The Astrophysical Journal …, 2016
Abstract Here we report an all-sky soft gamma-ray source catalog based on IBIS
observations performed during the first 1000 orbits of INTEGRAL. The database for the
construction of the source list consists of all good-quality data available, from the launch in ...

Underwater Systems having Co-Located Data Center and Water Desalination Subunits

BR Constantz - US Patent 20,160,075,569, 2016
Abstract: Underwater systems for data center cooling and water desalination are provided.
Aspects of the systems include a data center subunit and a desalination subunit that are co-
located with each other at an underwater location, where the desalination subunit is ...

METHODS AND APPARATUS TO PERFORM SITE RECOVERY OF A VIRTUAL DATA CENTER

M Duggan, KNM Rao - US Patent 20,160,077,919, 2016
Abstract: Methods, apparatus, systems and articles of manufacture to perform site recovery
of a virtual data center are disclosed. An example method includes discovering a work item
to be included in a protection group associated with a recovery plan. The work item is not ...

[PDF] Overview of Risk Management System of Commercial Bank Data Center

Z Li, S Yang, Z Li - 2016
Abstract In nowadays, the trend of the economic globalization is increasing evidently.
Without exception, all of the global banking industries take information technology as a
necessary condition for survival in the future and the core of the competition. Aimed at two ...

Mobile heater and fan system and methods of commissioning a data center

JD Sasser - US Patent 9,285,138, 2016
Abstract: A mobile system for simulating a thermal load and airflow expected in the operation
of a data center includes a thermal energy source, an impeller and impeller drive unit, an
outlet port, a frame and a ground engaging member. The thermal energy source provides ...

De-Risking Data Center Temperature Increases, Part 2

DLB PE, DQ PE - ASHRAE Journal, 2016
De-risking the process of raising temperatures in the data center involves many steps. In this
column, we address the remaining steps of the process we began in January's column. ...
De-risking the process of raising temperatures in the data center involves many steps. In ...

[PDF] Performance Evaluation of Secure Inter-Data Center Communication based on SDN

M Furukawa, K Kuroda, Y Ueno, N Miyaho
Recently, security in inter-data center communication has been attracting users attentions.
The existing data center communications are based on VPN technology using IPsec.
However, if there is an eavesdropper, on some route, there may be some risks that ...

Cost Minimization Algorithms for Data Center Management

L Shi, Y Shi, X Wei, X Ding, Z Wei
Abstract—Due to the increasing usage of cloud computing applications, it is important to
minimize energy cost consumed by a data center, and simultaneously, to improve quality of
service via data center management. One promising approach is to switch some servers ..